DIY degaussing coil

Degaussing Coil To Restore Gameplay Like It’s 1985

You may think that cathode ray tube (CRT) TVs and monitors have gone the way of the dinosaur, but you’d be wrong. Many still have them for playing video games at home or in arcades, for vintage computing, and yes, even for watching television programs. [Nesmaniac] uses his TV for playing Super Mario Bros but for several years it had a red area in the top right corner due to a nearby lightning strike. Sadly, it stood out particularly well against the game’s blue background. His solution was to make a degaussing coil.

Homemade degaussing coilWe have an article explaining degaussing in detail but in brief, the red was caused by that area of the metal shadow mask at the front of the display becoming magnetized by the lightning strike. One way to get rid of the red area is to bring a coil near it and gradually move the coil away. The coil has AC from a wall socket running through it, producing an oscillating magnetic field which randomizes the magnetic field on the shadow mask, restoring the colors to their former glory.

You’ll find [Nesmaniac’s] video explaining how he made it below. It’s a little cartoonish but the details are all there, along with the necessary safety warnings. His degaussing coil definitely qualifies as a hack. The coil itself came from a 15″ CRT monitor and his on/off switch came from a jigsaw. A 100 watt light bulb serves as a resistance to minimize current and if more or less current is needed then the bulb can be swapped for one with a different wattage.

To demonstrate it in action and give a few more construction details, we’ve included a second video below by [Arcade Jason] who made his for degaussing arcade game screens.

Continue reading “Degaussing Coil To Restore Gameplay Like It’s 1985”

WTF Is Degaussing?

The modern office has become a sea of LCD monitors. It’s hard to believe that only a few years ago we were sitting behind Cathode Ray Tubes (CRTs). People have already forgotten the heat, the dust, and the lovely high frequency squeal from their flyback transformers.

Image by Søren Peo Pedersen via wikipedia
Image by Søren Peo Pedersen via wikipedia

There was one feature of those old monitors which seems to be poorly understood. The lowly degauss button. On some monitors it was a physical button. On others, it was a magnet icon on the On Screen Display (OSD). Pressing it rewarded the user with around 5 seconds of a wavy display accompanied by a loud hum.

But what exactly did this button do? It seems that many never knew the purpose of that silly little button, beyond the light-and-sound show. The truth is that degaussing is rather important. Not only to CRTs, but in many other electronic and industrial applications.

 

Of Shadow Masks and Aperture Grilles

Close up of a shadow mask by Rauenstein via Wikipedia
Close up of a shadow mask by Rauenstein via Wikipedia

A CRT has quite a few components. There are three electron guns as well as steering and convergence coils at the rear (yoke) of the tube. The front of the tube has a phosphor-coated glass plate which forms the screen. Just behind that glass is a metal grid called the shadow mask. If you had enough money for a Sony screen, the shadow mask was replaced by the famous Trinitron aperture grille, a fine mesh of wires which performed a similar function. The shadow mask or aperture grille’s  job is to ensure that the right beams of electrons hit the red, green, or blue phosphor coatings on the front of the screen.

This all required a very precise alignment. Any stray magnetic fields imprinted on the mask would cause the electron beams to bend as they flew through the tube. Too strong a magnetic field, and your TV or monitor would start showing rainbows like something out of a 1960’s acid trip movie. Even the Earth’s own magnetic field could become imprinted on the shadow mask. Simply turning a TV from North to East could cause problems. The official term for it was “Color Purity”.

magnet-trickThese issues were well known from the early days of color TV sets. To combat this, manufacturers added a degaussing coil to their sets. A coil of wire wrapped around the front of the tube, just behind the bezel of the set. When the set was powered on, the coil would be fed with mains voltage. This is the well-known ‘fwoomp and buzz’ those old TV sets and monitors would make when you first turned them on. The 50 Hz or 60 Hz AC would create a strong moving magnetic field. This field would effectively erase the imprinted magnetic fields on the shadow mask or aperture grille.

Running high current through the thin degaussing coil would quickly lead to a fire. Sets avoided this by using a Positive Temperature Coefficient (PTC) thermistor in-line with the coil. The current itself (or a small heating coil) would heat up the PTC, causing resistance to increase, and current through the coil to drop. After about 5 seconds, the coil was completely shut down, and the screen was (hopefully) degaussed.

As time went on monitors became embedded systems. The PTC devices were replaced by transistors controlled by the monitor’s main microcontroller. Monitor manufacturers knew that their sets were higher resolution than the average TV set, and thus even more sensitive to magnetic fields. Users are also more likely to move a monitor while using it. This lead the manufacturers to add a degauss button to the front of their sets. A push of the button would energize the coil for a few seconds under software control. Some monitors would also limit the number of times a user could push the button, ensuring the coil didn’t get too hot.

Holding a magnet near the front of a black and white (or a monochrome ‘green screen’) CRT created visible distortion, but no lasting damage. Mid-century hackers who tried the same trick with their first color TV quickly learned that the rainbow effect stayed long after the magnet was moved away. In extreme cases like these, the internal degaussing coil wouldn’t be strong enough to clear the shadow mask.

Commercial degaussing coil
Commercial degaussing coil

When all else failed, a handheld degaussing coil or wand could be used. Literally waving the magic wand in front of the screen would usually clear things up. It was of course possible to permanently damage the shadow mask. Back in 2007, I was working for a radar company which had been slow to switch to LCD monitors. Being a radar shop, we had a few strong magnetron magnets lying around. One of these magnets was passed around among the engineers. Leaving the magnet under your monitor overnight would guarantee rainbows in the morning, and a shiny new LCD within a few days.

1024px-RMS_Queen_Mary_20Jun1945_NewYork
Queen Mary, showing her degaussing coil

CRTs aren’t the only devices which use degaussing coils. The term was originally coined in 1945 by Charles F. Goodeve of the Royal Canadian Naval Volunteer Reserve (RCNVR). German mines were capable of detecting the magnetic fields in a naval ship’s steel hull. Coils were used to mask this field. The Queen Mary is one of the more famous ships fitted with a degaussing coil to avoid the deadly mines.

Even mechanical wristwatches can benefit from a bit of degaussing. A watch which has been magnetized will typically run fast. Typically this is due to the steel balance spring becoming a weak magnet. The coils of the spring stick together as the balance wheel winds and unwinds each second. A degaussing coil (or in this case, more properly a demagnetizer) can quickly eliminate the problem.

A story on degaussing wouldn’t be complete without mentioning magnetic media. Handheld or tabletop degaussing coils can be used to bulk erase floppy disks, magnetic tape, even hard disks. One has to wonder if the degaussing coils in monitors were responsible for floppy disks becoming corrupted back in the old days.

So there you have it. The magic degaussing button demystified!